Blue Air Systems‘ energy–efficient mould dehumidification 

#

PRODUCT INNOVATION

Waterless DMS-technology for energy-efficient mould area dehumidification in a closed loop
Condensation free production conditions at low temperatures of cooling water on the mould.
Let`s start really saving energy: DMS-series: „Pure green technology“
Higher product quality, shorter cycle times and great potential for saving up to 85 % of energy

Injection moulding, thermo forming and blow moulding without condensation is possible. Blue Air Systems’  basic range of MSP-Dehumidification units (with process air volumes between 1.000 and 10.000 Nm³/h) was complemented with the new DMS series (Dry Mould System), a dehumidifier which works without the need for chilled water. An enclosed production area is supplied with dry air with a dew point of 4°C (39,2°F). The DMS dehumidification units with process air volumes ranging from 500 to 3.500 N³/h are now available.

The mould dehumidification units MSP are used mainly for supplying dry air to a central dehumidification system. The DMS series are specialized to be used for single production machines (up to 3 units). At the K 2016, the DMS system for high demanding injection moulding, extrusion blow moulding or thermo forming applications will be demonstrated to the trade visitors. As inventor of this game-changing technology, Blue Air Systems has spent three intensive years developing, testing and improving the system. The DMS units provide year-round, condensation- free production conditions, independent of ambient conditions, without the need for chilled water needed for pre-cooling. This energy-efficient technology guarantees the users of injection, blow moulding or thermoforming machines to run the shortest possible cycle times, therefore guaranteeing higher production output. The DMS series has been installed in various climatic areas, proving its performance. A number of references prove their efficiency and effectiveness.
 

 

Fig.: Dehumidification with the DMS unit (Dry Mould System) for packing, PET pre-form production and many other highly sophisticated applications

 

 

 

The phenomenon of condensation on tempered moulds
When the surface temperature of an object sinks below the dew point of the ambient air, condensation  builds on this object. This problem especially occurs on moulds of plastic processing machines that are cooled by chilled water. The cooling time, usually the longest part of the cycle time and one of the most sensitive steps of the manufacturing process is an important figure that influences the cost factor of the entire production process. By reducing the cooling water temperature of the mould, a shorter cycle time and subsequently a higher production output can be achieved. If the water temperature sinks below the dew point of the ambient air, the moisture in the air will condensate on the surface of the mould.

To avoid this condensation in facilities located in hot and humid climate zones, process engineers of manufacturing plants tend to increase the water temperature above the ambient dew point of the air. This standard procedure has a crucial disadvantage - the efficiency confines the effectiveness: increasing the cooling water temperature extends the cooling time of the item in the mould, thus reducing productivity and profit (rule of thumb: 1°C increase in cooling water temperature = 2% reduction of productivity). In many cases a longer cooling time increases the crystallization rates in the moulded plastic resulting in inferior product quality. Furthermore, condensation on the mould leads to possible water marks (“orange skin”) on the final product causing rejects or low product quality.


Limitations of conventional technology for mould dehumidification
A popular way of drying air for mould dehumidification is with the adsorption system. This technology, that uses a desiccant wheel for dehumidification, needs a comparatively high amount of energy. The energetic inefficiency occurs due to the use of large regeneration heaters, ventilators, motors and pre and after cooling with the need for chilled water. Mould dehumidification with the condensation technology, using a refrigerant system, is an alternative to the desiccant system. The MSP (Mould Sweat Protection) units based on this technology have been the backbone of Blue Air Systems for years. Many MSP units have been  installed in facilities worldwide. Thanks to their reliability and stability, these units bring their full performance even after many years and allow a condensation-free production with the optimal cooling temperature in the mould. A disadvantage of all dehumidifiers, whether they operate on the basis of adsorption or condensation drying, is that relatively large cooling loads are needed to pre-cool the ambient air. In many cases, the chilled water capacity of the facility is not dimensioned sufficiently to supply the necessary cooling load of chilled water. When investing in a new dehumidification system, besides the cost of the dehumidifier, the manufacturer also needs to take the cost of a new chiller, or the extension of the existing chiller system, into his investment calculation.

A look at the new, waterless DMS (Dry Mould System) in a closed loop
The DMS unit dries air on the basis of the condensation principle. The main difference to the standard systems is that the DMS is not constantly dehumidifying hot and humid ambient air. Instead, dry process air is circulated around the mould in a closed loop, bringing the air back to the DMS unit. By doing this, there is no necessity of using high cooling loads to dehumidify air, as the air returning to the DMS unit is partially dried. This procedure allows the DMS to work without a pre-cooler (chiller) and therefore no chilled water is needed for the DMS dehumidification.

A state-of-the-art refrigerant compressor of the newest technology automatically reduces the needed cooling capacity, as soon as reduction of moisture in the air is detected. Therefore, the DMS only uses electricity for the actual cooling need of the refrigerant system.

 

  Fig.: Functional Principle DMS (Dry Mould System): The process air is run in a closed loop, circulating back to the DMS unit for pretreatment and dehumidification of the air to a 3°C dew point. The MPSCS (Micro Processor Controlled Segment Condensation) technology guarantees perfect and consistent conditions at the lowest possible energy consumption.

 


Model calculation:
Mould dehumidification with only 85 % lower energy consumption, compared to conventional systems
Standard dehumidification systems on the market are supplied with a water pre-cooler. The DMS units do not need the chilled water for pre-cooling, which automatically reduces overall investment costs for such a  system between 15.000 and 20.000 Euros. A pre-cooler in standard systems, requires only 66 % or less of the overall energy normally needed. By cutting out the pre-cooler, immense cost and energy savings can be achieved. In production, the actual savings can seen: For example, a dehumidification unit with a desiccant wheel and a process air volume of 1.800 Nm³/h needs a cooling capacity of 38.700 kcal/h (45 kW) (calculated at ambient conditions of 35°C/ 60% rel. hum.), which adds up to 45 / 3 = 15 kW of electrical energy needed to run the chiller.


For the regeneration heater, blower and motors, an additional 20 kW of electrical energy is needed for the dehumidifier. The total electrical consumption of the dehumidification and the electricity for the chiller adds up to 15 kW/h + 20 kW/h = 35 kW/h. This is a large amount of
energy when compared to the DMS unit, which runs with an average of 5 kW, as only electrical energy is needed for the refrigerant compressor and the ventilators. The difference of 30 kW/h or in other words, 86 % reduction, is extreme. If you calculate for example 0,15 EUR/kW and consider a 24/7 production with 168 hours production time per week, the immensity of the savings becomes clear: 30 kW x 0,15 x 168 h = 756 EUR per week, or 3.024,00 EUR per month (á 4 weeks). Hard earned money is saved so easily, day by day, every day. It is just as easy to calculate the short amortization time of the DMS unit.


   Fig.: The compact DMS series can easily be integrated into a manufacturing cell due to the marginal foot print it leaves behind, physically as well as ecologically.

 

 

 

 

Effective mould drying with the DMS means you save large amounts of energy, too
The installation of the DMS unit is easy and effective. The installation of insulated water pipes to and from   the chilled water source is no longer necessary. Only the connection to the electricity supply is required. With the application of refrigerant compressors and ventilators of the youngest generation, significant energy savings can be achieved. These systems control and adapt the required cooling capacity to the ambient conditions, with the help of intelligent sensor technology. If the chilled water capacity is not enough, with the DMS application, no extra investment into an additional chilled water supply is necessary. The manufacturer has the advantage of saving double, once with the investment and a second time during operation. The DMS is a tailor-made system, allowing the manufacturer to choose to supply dry process air volumes from units ranging 500 to 3.500 Nm³/h.

Smart dehumidification with the DMS Series
The DMS units are made of high quality, perfectly balanced components to allow optimal energetic mould dehumidification. Until now, no comparable systems exist on the market. The process air is run in a closed loop, always brought back to the DMS unit for pretreatment and dehumidification of the air down to a 3°C dew point. The process air is dried by simulating a cold object in the DMS unit (similar to the mould) that allows the moisture in the air to condensate in the DMS unit, before it reaches the mould. The DMS unit cools and dehumidifies the air in a 2 step refrigerant unit with the MPCSC technology (Micro Processor Controlled Segment Condensation). For this version, only electrical energy is needed. A DMS 15 supplies a nominal process airflow of 1.500 Nm³/h. The larger DMS 25 dehumidifies 2.500 Nm³/h and the DMS 25+ up to 3.500 Nm³/h. Just like the ecological footprint, the actual footprint left in the production hall with the dimensions of a DMS 15 of 900 x 1300 mm is remarkably small.


Sophisticated areas of application
The DMS units are designed for all applications where sophisticated, high-performance moulds are  cooled with chilled water and which are located in areas where moisture in the air can condensate on the mould. So, generally speaking, all injection molding, extrusion blow moulding and thermo forming systems. Core areas in the plastics industry are packaging systems such as caps and PET performs, as short cycle times of the process and high production outputs require chilled water.

Bernhard Stipsits, managing director of Blue Air Systems: “The DMS units from Blue Air Systems guarantee condensation-free production conditions in a closed system, even when using very low chilled water temperatures for the moulds throughout the year, being independent from ambient climatic weather conditions. The MPSCS (Micro Processor Controlled Segment Condensation) technology provides controlled parameters at all times, making sure the optimal energetic conditions are automatically adjusted. What you get is higher productivity and consistent product quality in the production process at the lowest possible energy consumption. It’s time to start reducing our ecological foot print and the DMS is a huge step in this direction!”

 

   Fig.: Condensation-free production conditions with the DMS unit: dry air circulates around the mould in an enclosed environment – more performance, less energy and consistent product quality.

 

 

 

 

 

Blue Air Systems, an over view   

Blue Air Systems, an Austrian-based company, founded in 2010, located in Kundl/Tyrol supplies the plastics industry with innovative technology. Core subject is climate technology with solutions for extremely dry and cold air for energy efficient processing in the plastics industry.

Blue Air systems not only develops high quality applications, but also safe and easy to use, Plug and Play solutions, to keep energy consumption and service intervals at an absolute minimum. In addition, Blue Air Systems provides consulting services in the application of our machines and technology. In climate  technology solutions, the core business is focused on dehumidification units (Series BAS-MSP and BAS-DMS) and internal product cooling (BAS-CAC) to effectively cool blown parts on blow moulding extrusion machines with extremely dry and cold compressed air (-35°C) (process volumes from 120 to 540 Nm³/h). The CAC units reduces material stress noticeably as well as cycle time up to 50%.

For material handling solutions, Blue Air Systems offers a wide range of state-of-the-art compressed air dryers for effective and energy-saving material drying (Series RDM, RDX and RDL). Using pre-dried compressed air from the compressed air network available on site, the RD system dryers are an economical option to conventional material drying systems, such as desiccant dryers. The compressed air dryers with hopper sizes ranging from 2 to 82 liters for best drying performances – resin for resin, with minimal operating cost and virtually no maintenance.

A worldwide network of sales and service centers located at representatives guarantees long-term and optimal customer liaison and support as well as maintaining the value of machines and installations. Constant growth, worldwide references, innovative technologies and maximum quality standards make Blue Air Systems a reliable global partner for the plastics industry.